Not to be outdone by the Brit's, in the weeks that followed, an American archaeologist dug to a depth of 20 feet, and shortly after, a story published in the New York Times:"American archaeologists, finding traces of 250-year-old copper wire, have concluded that their ancestors already had an advanced high-tech communications network 50 years earlier than the British".

In Canada,
One week later, Canadian Dept of Mines and Resources in Northern Canada reported the following:"After digging as deep as 30 feet in Northern Canada in the Ontario region of Thunder Bay Jack Lucknow, a self-taught archaeologist, reported that he found absolutely nothing. Jack has therefore concluded that 250 years ago, Canada had already gone wireless."

Just makes you bloody proud to be Canadian, don't it!

Thursday, April 29, 2010

Using Correct Conductivity Temperature Compensation

This article was written by Lori L. McPherson.

When this article was written Lori L. McPherson, B.S. Chem E., was the analytical Specialist for Georg Fischer, Inc., Tustin, California.

Conductivity measurements are normally used to interpret the quantity of ions contained in the solution. The temperature of the solution can have a large effect on the reading. Most conductivty instruments will "Compensate" for this conductivty affect, allowing the reading to be standardized to an estimated value at 25 deg. 'C'. For water solutions, a temperature compensation factor, or coefficient of 2 percent per degree celtigrade, is normally used. This compensation is reasonably accurate on the conductivity measurement. However, in solutions other than water the actual coefficient ma be significantly different, and if not programmed correctly can result in a very large measurement errors.

The Conductivity Measurement

The conductivity measurement is literally a measure ment of of the solution's ability to conduct electricity. It is directly affected by the number of disolved ions in the solution. As the number of disolved ions increases, the ability to conduct electricity also increases. The measurement Value is generally considered to be a measurement of the actual number of ions contained in the sample, while in fact, this is only inferred.

The conductivuty measurement measurement unit is the inverse of the resistivity measurement. Resistivity measures the solution's ability to resist electrical current flow.This is measured in Ohm*cm. Therefore, conductivity mhos/cm, with mhos being defined as Ohms-1. This unit has been renamed by the international standards organization to be Siemen (S). However, both mhos/cm and S/cm are considered correct. In clean water (surface water, well water, etc.), the order of magnitude is in the range of 10-6 S/cm or uS/cm. ( us/cm = micro seimens).

The Affect of Temperature on Conductivity

The solution's ability to conduct electricity is related to the concentrationnand specific conductivity of the ions in the solution, and the temperature of the solution. Increased temperature provides increased activity or ionic movement that enables more electricity to be carried through the solution from one electrode to another.

In order to better correlate the electrical conductivity to the concentration of ions, the affect of temperature on the solutions ability to conduct electricity is subtracted from the actual conductivity. For example, a solution at 25 deg 'C' may conduct 200 uS. This same solution at 35 deg 'C' would conduct 240 uS. Since the primary purpose of the measurement is to correlate to the purity of the solution, the affect of temperature is subtracted (compensated), with a displayed, compensated value shown at 200 uS. This provides a means of standardizing the conductivity reading to a concentrationof ions at 25 deg 'C'.

Applications with Coefficients Different from Water

Many solutions other than water are effectively controlled using conductivity. Some of these include offset printing fountain solutions, water soluble lubricants used in metal machining and quenching solutions. many of these solutions have been tested to determine their temperature coefficients, and have been found to have coefficients significantly different than the 2.0 perecnt per degree celcius used for water solutions. If the coefficient used is incorrect, when the temperature of the solutions change, the conductivity value will be seen to change. However, in reality, the concentration in the solution remains the same.

Other solutions, such as acids or bases, can also have temperature coefficients significantly different than that of water. In many cases, each concentration range of a solution will have it's own temperature coefficient. For example, 10 percent sulfuric acid will have a muuch diufferent temperature coefficient than 50 percent, and those values will be different than sulfuric acid at 90 percent. To maintain the highest level of accuracy across temperature changes, it is recommended to check the temperature response of the solution, and program the instrument accordingly.

Applications that Should Not be Temperature Compensated

In some applications, the measurement of the true or actual electrical conductivity is important, without any standardization back to the conductivity level at 25 deg. 'C'. One example of this type of application is the salt solution used to shock poultry prior to processing. The salt content of this solution is monitored using conductivity, to ensure that it can carry sufficient current to effectively stun the chicken. In this case, the temperature compensation program should be deactivated (generally by introducing a coefficient of 0.0 per degree celcius). This activity guarantee that thsi measurement is a true measurement of the electrical current the solution will pass, and the process will operate as needed.

A second example is the reionization of pure water to prevent carona discharge across high pressure nozzles.In the semiconductor industry, the water used in rinsing wafers must be free of any impurities. In thuis state, the water generally has a resistivity associated with it of 18.3 Mega Ohms. Unfortunately, water this resistive can cause a static, or corona discharge when the water passes through a high pressure spray nozzle. This discharge, or sparking, can badly damage the wafer being washed. By re-ionizing the water with carbon dioxide, the water regains some ability to conduct electricity, without salt contamination, and the discharge is prevented. In this case, the electrical property of the solution is the important property, not it's inference to the content of carbon dioxide. Therefore, temperature compensation should not be used for optimum process control.

Determining the Temperature Coefficient

For many chemicals, the temperature coefficient may be obtained from published data such as that found in "Dobo's Electrochemical Data" . If the data is not available, it can be determined experimentally quite easily.

It is important to realize that the function of temperaturecompensation is to normalize the reading back to that which would occur at 25 deg.'C'. This is the referencepoint for the determination of the temperature coefficient. In other words, the coefficient defines the change in conductivity per each degree celcius change in temperature, from the reference or starting point of 25 deg. 'C'. Using water as an example, with a 2 percent per degree celcius coefficient (TC=0.02), the coefficient defines the conductivity increase as 2 percent of the reading at 25 deg. 'C'. A 1000 uS solution at 25 deg 'C' would increase 20 uS in conductivity with each one degree celcius temperature change.If the temperature range is 40 to 50 deg. 'C', the relationship to temperature must be linearized back to give a conductivity readingat 25 deg. 'C' to eastablish a correct temperature coefficient. This is the basis for the calculation below for determining the coefficient from the conductivity values at two different temperatures:

C1 = C25 * (1+(TC*(T1-25))

Using two data points at temperatures other than 25 deg. 'C' (for ease of experimentation), and solving the two equations for C25, enables the determination of the TC to be simplified to the following equation:

TC = (C1-C2) / C2 (T1-25) - C1 (T2-25)

Where C25 is the conductivity (reference) at 25 deg 'C', C1 is the conductivity at temperature T1, and C2 is the conductivity at temperature T2.

When obtaining values for C1 (@T1) and C2 (@T2), it is critical to disable any tremperature compensation in the instrument. this is normally accomplished by setting the coefficient to 0.0 percent per degree 'C'.Once this has been done, the readings taken at the two temperatures will be raw conductivity values, and can be used in the calculation. It is recommended that the two points used represent the maximum range of temperature for the application being tested. Furthermore, allowing time for the temperature to stabilize, and taking several readings for statistical averaging will greatly increase the accuracy of thsi determination.

Non-Linear Temperature Compensation

In some situations, temperature compensation does not follow a clean, linear relationship as defined above. The most common of these applications is pure water, in the resistivity range of 1 to 18.3 Mega Ohms * cm. For this application, resistivity instruments are pre-programme for the exponential response to temperature that can occur. A linear compensation program would be highly inaccurate for thisapplication, especially i temperatures below 25 deg. 'C'

Wednesday, April 14, 2010

A Simple Test Could Save Your Life ! ! !

A Simple Test Could Save Your Life
Written by: William Ball

If you use a personal safety gas monitor in your job, you need to be aware that taking a few seconds to perform a "Bump Test" every day could mean the difference between going home to your family at the end of the workday and becoming another industrial workplace fatality

The "National Institute for Occupational Safety and Health (NIOSH) estimate millions of workers globally may be exposed to hazards in confined spaces, and every year a large number of those workers become workplace fatality statistics. Those killed include not only the individuals working in the confined space, but frequently those who attempt to rescue them. Confined spaces are encountered in a wide variety of industries including:

• Mining
• Construction
• Water and sewer operations
• Oil and Gas, Petrochemical
• Shipping vessel and aircraft maintenance

Sewers, underground cable vaults, tanks/vessels, silos, and aircraft wings are easily identified as confined spaces. Others may not be so obvious, for example opened topped chambers, vats, manure pits, unventilated or poorly ventilated rooms.

Global confined space statistics show that the Majority of confined space fatalities result from hazardous atmospheric conditions. In Australia it is estimated that in 75% of confined space accidents the atmosphere was not tested prior to entry. The lack of proper training and understanding the inherent hazards are the key contributing factors to confined space accidents. Awareness of potential hazards is essential to any confined space safety program and testing the atmosphere wit an appropriate, properly functioning, safety gas detector is the only way to determine whether it is safe to enter.

After a confined space has been cleared for entry it is essential to monitor continuously while workers occupy the space. Atmospheric conditions can change without warning ! Work activities in confined spaces such as welding, painting and degreasing, to name a few, can produce dangerous atmospheric conditions. Atmospheric hazards can also come from sources outside of the confined space. Many atmospheric gas hazards are colourless and odourless so monitoring with an appropriate safet gas detector is essential to protecting workers.

Everyday workers around the world trust their portable safety gas detectors to warn them of possible life threatening atmospheric gas hazards, often with little understanding of how these important pieces of safety equipment work. Serious injury or death can be caused by exposure to toxic gases, oxygen deficient environments or explosions caused by the combustible gases.

Why is “Bump Testing” Necessary ?
Portable gas detectors can contain various types of sensor technologies with different detection principles. The most common configuration in a confined space entry gas detector includes sensors for the detection of Oxygen concentration and the presence of Hydrogen Sulphide, carbon monoxide and combustible gases. Workplace environments can be harsh and gas detectors are subjected to all kinds of conditions that can and do affect their operation. Instruments can be physically damaged, sensor ports can become obstructed by dirts and oils, sensors can be damaged by exposure to gas concentrations that exceed their detectable limit, and sensors can be exposed to compounds in the atmosphere tha can degrade their performance.

The catalytic hot bead combustible sensor used in many safety gas detectors is particularly prone to damage by compounds that can be encountered daily in the workplace environment. This type of combustible gas sensor contains two coils of very fine platinum wire coated with ceramic or porous alumina material to form refractory beads. The beads are connected to opposing arms of a balanced Wheatstone Bridge Electrical Circuit. One bead (Active) is additionally coated with Platinum or Palladium, which enables catalytic oxidation of combustible gases at concentrations below the Lower Explosive Level (LEL) to occur. The opposing bead (Reference) is identical in structure except it has been poisoned so that the catalytic oxidation cannot occur. Both beads are heated to specific temperature and in normal air, the wheatstone bridge circuit remains balanced. If combustion gas is present, catalytic oxidation will heat the active bead to a higher temperature than the opposing reference bead, unbalancing the electrical resistance in the wheatstone bridge. The difference in the electrical resistance of the active bead versus the reference is proportional to the concentration of the combustible gas in the atmosphere.

One of the limitations of this catalytic bead technology is that the sensor is potentially prone to damage through exposure to airborne contaminants capable of impairing sensor performance, or permanently destroying the sensor. Some airborne substances can decompose on the active sensor bead catalyst and form a solid barrier over the catalyst bead surface, effectively poisoning the sensor. Silicone vapours are the most commonly encountered workplace substance capable of destroying catalytic bead sensors. Many commercially available lubricants, rust inhibitors, adhesives and cleaners contain silicone based compounds. Some other poisons to be aware of are compounds containing lead, Sulphur or phosphates and high concentrations of combustible gases. A single exposure to a high concentration of a sensor poison can destroy the catalytic bead combustible sensor, or sensors can lose sensitivity gradually as a result of chronic exposure to contaminants.

Halogenated compounds such as chlorinated hydrocarbons and chlorofluorocarbons are absorbed by the active sensor catalyst inhibiting the sensor response. Exposure to these compounds is typically temporary and once the detector is removed from the contaminated environment the sensor will recover normal sensitivity. In some cases, chronic exposure to inhibitors will permanently damage the catalytic bead combustible sensor.

Electrochemical sensors used for the detection of toxic gases such as carbon monoxide and hydrogen Sulphide are not as prone to poisons as the catalytic bead sensor, but their performance can also be compromised by certain ambient contaminants. Many electrochemical sensors can be temporarily or sometimes permanently damaged by exposure to organic solvents and alcohols. Methanol, which is one widely used in many parts of the world during the cold winter months, can have a profound effect on CO and H2S sensors. Many insect repellants contain alcohol and use hydrocarbons such as propane or butane as an aerosol propellant. Both can affect gas detector sensors. High concentrations of solvents can also affect internal components of the electrochemical toxic and oxygen sensors resulting in permanent damage.

Unfortunately , even though the gas detector performs diagnostic checks at start up and during operation, it is often not possible to electronically detect a problem with sensor response. The detector cannot warn users that the sensor ports are obstructed by dirt, oil or some other substance. or that the capillary pore of an oxygen sensor is blocked, or that the catalytic bead of a combustible sensor has been poisoned. A personal safety gas detector cannot properly protect a worker if gas molecules cannot get into the sensor or if the sensor’s ability to detect the target gas has been compromised.

The only way to confirm that a gas detector is functioning, and is capable of responding to gas, is to expose the instrument to a concentration of target gas high enough to initiate an alarm situation while the instrument is in operating mode. This procedure is often referred to as performing a “Bump Test” and is key to the safe use of portable safety gas detection equipment.

How often should I bump test or calibrate?
At minimum follow the safety gas detector manufacturer’s recommendations for bump testing and calibration frequency. Additional testing of a gas detector should also be performed if a detector has been subjected to any of the following circumstances:

1. Chronic exposure to, or used in, extreme environmental conditions, such as high/low temperature and humidity, and high levels of airborne particulates.
2. Exposure to hi (over range) concentrations of the target gases or vapours.
3. Chronic or acute exposure of catalytic “Hot-Bead” LEL sensors to poisons and inhibitors. These include:
• Volatile Silicones
• Hydride Gases
• Halogenated Hydrocarbons
• Sulfide Gases
4. Chronic or acute exposure of electrochemical toxic sensors to:
• Alcohols
• Solvent Vapours
• Highly corrosive Gases
5. Harsh Storage and operating conditions, such as when a portable gas monitor is dropped onto a hard surface or submerged in liquid. Normal handling/jostling of the monitors can create enough vibration and or shock over time to affect electronic components and circuitry.
6. Change in custody of a monitor.
7. Change in work conditions that might have an adverse effect on sensors.
8. Any other conditions that would potentially affect the performance of the monitor.

Bump Testing has to be a part of any safety program !
In the evolution of safety gas detection instrumentation “Bump Testing” is a relatively new practice. Calibration of gas detection equipment is part of routine maintenance. There was a time when manufacturers recommended frequent, even daily calibration, but as sensor technology and sensor performance became better understood, the frequency of calibration lengthened. As calibration frequency decreased it was just assumed that the detector was operating properly between calibration intervals. Today, although recommended calibration frequency may vary considerably from one safety gas detector manufacturer to the next, there is unanimous agreement amongst manufacturers that it is necessary to bump test detectors between calibrations. Again, there is no manufacturer consistency in the wording of the Bump Testing recommendation found in gas detector manuals. Gas detector users cannot be blamed if they are confused and do not understand why Bump Testing is necessary. As a result the practice is often not adopted and in some areas of the world Bump Testing personal gas detectors between calibration intervals is virtually unheard of.

The concept of a Bump Test I to verify the detector sensors respond to a target gas and that the detector alarms activate. This is sufficient for many users, but others perform a calibration check, confirming the accuracy of the sensor response while testing.

Sensor Calibration adjusts response accuracy and Bump Testing verifies sensor response between calibration intervals. Performing a Bump Test takes only seconds and provided gas detection users with confidence that the detector about to be used is working. Be sure to use test gas for a reliable source, and check the expiry date on the cylinder. If a detector does not pass the Bump Test protocol do not use it. Additional testing should be done to diagnose the cause.

With the development of automated Calibration and Bump Test systems, the process can be as easy as pushing a button. Many automated systems keep a permanent record of each test performed so that in the event of an accident investigation detailed proof of proper maintenance and testing can easily be produced. Records of manual Calibration and Bump Testing must also be kept. Remember if it wasn’t recorded, it wasn’t done!

Increased safety awareness and improved safety practices do make a difference. According to the U.S. Department of Labour, Industrial fatalities in 2006 were at the lowest rate since the fatality census began in 1992. In 1992 the number of fatal work injuries per 100,000 workers was 5.2; In 2006 the figure was down to 3.9. In Britain the same trend in workplace fatalities is evident. Since the introduction of the health and safety at work act an 1974 work related deaths have decreased approximately 35%. In 2005/2006 the number of fatalities was at the lowest level ever recorded. Fewer fatalities are the result of increased awareness and improved safety practices.

Most confined space deaths that result from exposure to lethal atmospheric conditions could have been prevented . Implement an effective confined space entry program and appropriate safety equipment . Most atmospheric gas hazards are imperceptible to human senses, so testing the atmosphere prior to entry and continually monitoring for changes in conditions using a properly working personal safety gas detectors is essential to keeping workers safe. As a minimum requirement, Bump Testing a safety gas detector prior to each days use should be a part of any effective confined space entry safety program.




Author Details:
William Ball
Product Applications and Training Specialist
Honeywell Life Safety
BW Technologies by Honeywell
2840 – 2 Avenue SE
Calgary, Alberta
T2A 7X9
www.gasmonitors.com